Particle counter to measure the concentration of contaminating particles in the atmosphere / data memory / mini B-USB interface
The MicroDust Pro CEL-712 dust monitor measures the concentration of particles and microparticles such as dust, smoke, pollen, and other aerosols found in the air. This dust monitor has been developed to accurately detect the degree of air pollution. Pollution is primarily generated by combustion, material processes, manufacturing, energy production, vehicle emissions, and in the construction industry. With the help of the dust monitor, you can measure the precise concentration of contaminating particles in the air. These dispersed particles are responsible for reduced visibility, the spread of pollutants, inhalation of toxic substances, and therefore reduced work effectiveness. It has long been known that particles can be one of the causative agents of diseases such as asthma, bronchitis, skin diseases, and respiratory diseases. Traditional gravitational methods of particle measurement require a considerable testing period and are not always suitable for assessing real-time concentration trends. Therefore, this dust monitor is ideal and portable for real-time assessment of dispersion particle concentrations. Accurate and reproducible particle concentration measurements are achieved using proven progressive light scattering techniques. This dust monitor allows for graphical presentation and assessment of concentration trends, internal recording of measurement values, and transmission to a PC or laptop whenever desired. Simple interfaces and digital calibration methods are available for any particle observation scenario. The ability to store measurement values and transmit and assess data makes the dust monitor an ideal tool for professionals and experts. The color display of the dust monitor has a particularly high resolution and can show both text and graphical information. It displays configuration details, pollution levels, logging information, and battery status.
- Wide measurement range:
0,001 mg/m³ ... 2500 mg/m³
- Internal data memory for 86,000
registros
- Removable sensor for recognition of
problem areas, e.g. checking
filtros
- Software Casella Insight PC
- Display with real-time graphical diagrams
real
- Possibility of component power supply
AC power, battery or batteries
- Alarm function at limit values of
definable concentration
Technical specifications
Dimensions
Measurement range
0,001 ... 2500 mg/m³
Resolution
0,001 mg/m³
Estabilidad cero
2 µg/m³
Alarm output
Interruptor "Open Drain" <15V & 500mA DC
Power supply
Battery / Operating time
3 x AA/ MN 1500 digits / approx. 13 h.
Power supply externa
12 V DC (via a PC18 power supply)
Analog output
0 - 2,5V DC FSD
Physical data
Pantalla
Color display for precise indication
of all information
Memory capacity
86.000 valores
Memory range
1 second to 1 hour
Puerto
Mini-B-USB
Analog output
0... 2,5 VDC
Dimensions (aparato):
172 x 72 x 33 mm
Dimensions (Sonde):
35 x 205 mm
Peso
<600 g (batteries included)
Temperatura operativa
0 ... +55 °C
Support fastening
1/4" Whitworth connections
Software
The Casella Insight data logging software supports the logging functions of the dust monitor. It has been specially designed to facilitate instrument setup processes, data querying, and presentation. Another advantage of the Casella Insight data logging software is that it automatically recognizes if used with a Spanish-speaking computer system.
Pantalla
The MicroDust pro CEL-712 dust monitor features a color display. It can represent measurement results as real-time graphs (with freely scalable time axis) or numerical values as pure numerical values.
They can also be presented as "Time Weighted Average" (TWA) and as the maximum value of particle concentration. The previous settings and the measurement values stored in the dust monitor can be cleared at any time using the "Reset" key. It is sufficient to press the key once.
Contents of the shipment
1 x MicroDust pro CEL-712 dust monitor
1 x Transport case
1 x Calibration adapter
1 x Factory calibration certificate
1 x Cleaning blower
3 x AA Batteries
1 x Cable USB
1 x Software Casella Insight
1 x User manual and field guide (pendrive)
Information:
Recommendation:
Metrological calibration certificate of:
Technical service and maintenance of:
Dust monitor
Dust monitor
International calibration certificate:
220 US$
Preventive maintenance and verification:
35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025
30 US$
Repair, corrective maintenance, adjustment, update, and validation:
60 US$
Includes:
** 2-year warranty.
** Discounts for the sale of two or more Dust monitor.
** Metrological calibration certificate for Dust monitor.
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a:Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.