includes sound, light, temperature, humidity, and external temperature sensor
(Type K) and digital multimeter with automatic range / large LCD display / optional infrared temperature adapter
This multifunction digital luxmeter combines an environmental meter with an automatic range digital multimeter. The multifunction luxmeter, designed with a compact and easy-to-use rubber housing, offers a wide variety of functions. It covers many measurement parameters such as resistance, capacitance, frequency, current, voltage, temperature (internal and external via K-type connection), acoustic continuity test, transistor testing, noise level, and light measurement. Additionally, it features an automatic range and the 'Data-Hold' function, as well as a large backlit display. This multifunction luxmeter is suitable for use in industry, electrical workshops, services, schools, universities, hobbyists, etc. The combination of different environmental parameter measurements allows for comfortable use in virtually any location. Optionally, we offer an infrared temperature adapter for non-contact measurement in a range of -30 ... +500 ºC.
- Easy-to-read 3 4/5-digit LCD display
with backlighting
- HOLD function
- Battery status indication
- Robust rubber-coated housing
- The multimeter integrates a range selection
automatic
- Measures noise level, lux, temperature
external through K-type thermoelement,
ambient temperature and humidity
- Opcionalmente puede adquirir un adaptador
infrared temperature
Technical specifications
Light meter
Measurement ranges
4000 / 40.000 lux
(Lux range of 20,000 = indicator x 10)
Range exceeding
"OL"
(must select a higher measurement range)
Accuracy
±5 % of the measurement value + 2 digits
Reproducibilidad
±2 %
Temperature feature
±0,1 % / °C
Sensor
silicon photodiode with filter
Sound level meter
Measurement range
35...100 dB
Resolution
0,1 dB
Frequency range
30 Hz...10 kHz
Frequency valuation
rating C
Temporal valuation
fast
Accuracy
± 5 dB
at 94 dB, sinusoidal signal of 1kHz
Microphone
electric condenser microphone
Moisture meter
Measurement range
33...99 % H.r.
Resolution
1 %
Accuracy
±5 % of the measurement value + 5 % H.r.
Temperature meter
Measurement range
0 ... 50 °C
Resolution
0,1°C
Accuracy
±3 % of the measurement value ±3 °C
Type K thermocouple connection.
Measurement range
-20 ... 400 ºC
-20 ... 1300 ºC
Resolution
0,1 ºC
Accuracy
±5 % of the measurement value + 3 ºC
Multimeter
Measurement range
- DC voltage
- AC voltage
- Corriente DC
- Corriente AC
- Resistencia
- Capacidad
- Frecuencia
400 mV / 4 / 40 / 100 / 250 V
400 mV / 4 / 40 / 100 / 250 V
400 / 4000 µA / 40 / 400 mA / 10 A
400 / 4000 µA / 40 / 400 mA / 10 A
400 Ω / 4 / 40 / 400 Ω / 4 / 40 MΩ
50 / 500 nF / 5 / 50 / 100 µF
5 / 50 / 500 Hz / 5 / 50 / 500 kHz / 10 MHz
Resolution
- DC voltage
- AC voltage
- Corriente DC
- Corriente AC
- Resistencia
- Capacidad
- Frecuencia
0,1 / 1,0 / 10 / 100 mV / 1 V
0,1 / 1,0 / 10 / 100 mV / 1 V
0,1 / 1 / 10 / 100 µA / 10 mA
0,1 / 1 / 10 / 100 Ω / 10 kΩ / 1 MΩ
10 pF / 0,1 / 1 / 10 nF / 0,1 µF
0,001 / 0,01 / 0,1 / 1 /10 / 100 Hz / 1 kHz
Accuracy
- DC voltage
±1 % of the value ±4 digits (up to 40 V)
±1.5% of the value ±4 digits (above)
- AC voltage
±1.5% of the value ±15 digits (up to 400 mV)
±1 % of the value ±4 digits (up to 40 V)
±1.5 % of the value ±4 digits (up to 100 V)
±2 % of the value ±4 digits (up to 250)
- Corriente DC
±1 % of value ±2 digits (up to 40 mA)
±1.2 % of the value ±2 digits (up to 400 mA)
±2 % of the value ±5 digits (up to 10 A)
- Corriente AC
±1.2 % of the value ±2 digits (up to 40 mA)
±1.5 % of the value ±2 digits (up to 400 mA)
±2 % of the value ±5 digits (up to 10 A)
- Resistencia
±1.5 % of the value ±4 digits (up to 400 Ω)
±1.5 % of the value ±2 digits (up to 400 kΩ)
±2 % of the value ±2 digits (up to 4 mΩ)
±2.5 % of the value ±5 digits (up to 40 mΩ)
- Capacidad
±5 % of the value ±20 digits (up to 50 nF)
±3 % of the value ±5 digits (up to 50 µF)
±4 % of the value ±5 digits (up to 100 µF)
±1.2 % of the value ±3 digits (up to 500 kHz)
±1.5 % of the value ±4 digits (up to 10 MHz)
Overvoltage category
CAT II 600 V / CAT III 300 V
Observaciones generales
Pantalla
LCD display, 3 4/5 digits
Overrange indicator
"OL"
Measurement sequence
approx. 3 per second
Temperature for indicated accuracy
23 °C ± 5°C / <70 % H.r.
Condiciones ambientales
0...+40 °C / <70 % H.r.
Storage conditions
-10...+60 °C / <80 % H.r.
Power supply
1 x 9 V battery
Device dimensions
170 x 78 x 48 mm
Peso
335 g
Contents of the shipment
1 x Multifunction Lux Meter PCE-EM 886
1 x Type K temperature sensor
1 x Test leads
1 x 9 V Battery
1 x User manual
More information:
Recommendation:
Metrological calibration certificate of:
Technical service and maintenance of:
Luxmeter
Luxmeter
International calibration certificate:
220 US$
Preventive maintenance and verification:
35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025
50 US$
Repair, corrective maintenance, adjustment, update, and validation:
60 US$
Includes:
** 2-year warranty.
** Discounts for the sale of two or more lux meter.
** Metrological calibration certificate for luxmeter.
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a:Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.