Gas detector for 4 gases (ATEX I M2: EEX lb dI, ATEX II 2G, Ex ias IIC T4)
for quick on-site measurements or prolonged measurements
More than 40,000 Triple Plus + gas detector devices with internal data memory are in operation worldwide. The measurement accuracy, robustness, measurement value memory and software make this gas detector an essential item for daily use on the construction site or in the company.
The gas detector displays the current measurement value on the screen and alerts the user through optical and acoustic alarms. The gas detector detects four gases simultaneously: you can see the different sensors in the technical specifications section and request them in the online store. Another advantage is the internal memory. Measurement values can be stored continuously and later transmitted to a PC for evaluation. The gas detector's data logger can be pre-configured so that the device can autonomously store data at the desired location without the need for personnel. There is another model of gas detector but only for detecting a single gas, you can see it Gasmann N.
- Suitable for use in the Ex sector (Ex ias IIC T4 / Class I, Division I, Groups A, B, C, D / EN50014, EN50020, SFA3009 / UL 913 / CSA22.2 / EN50081-2/ EN50082-1 / Sira 02 ATEX 2176X Ex ib d IIC T4, ATEX I M2: EEX lb dI ATEX II 2G)
- Solid TRIAX housing.
- Suitable for industrial use.
- Acoustic alarm (85 dB (A) at 1 m) and optical with flashing alarm LEDs.
- Availability lamp that blinks to show operational capacity.
- Large display with 4 gas indicator.
- Simple calibration.
- Memory function / data logger for 6000 measurement values per parameter.
- All types of sensor combinations.
- Protection type IP 65.
- Power supply with rechargeable battery.
- Delivered with transport tape.
Front view of the Triple Plus + gas detector
Side view of the Triple Plus + gas detector
Technical specifications
Measurement parameter
Measurement range
Alarma
Gases inflamables CHx
0 – 100 Vol.% LEL
20 % LEL
Gases inflamables CH4
5 – 100 %
20 % LEL
Oxygen O2
0 – 25 %
19 % & 23 %
Carbon dioxide
0 - 5 %
0,5 - 1,5 %
Hydrogen sulfide H2S
0 – 50 ppm
10 ppm
Carbon monoxide CO
0 – 500 ppm
30 ppm
Sulfur dioxide SO2
0 – 10 ppm
2 ppm
Cloro Cl
0 – 5 ppm
0,5 ppm
Nitrogen dioxide NO2
0 – 10 ppm
2 ppm
Fosfinas PH3
0 – 2 ppm
0,5 ppm
Amonio NH3
0 – 50 ppm
25 ppm
Hydrogen H2
0 ... 2000 ppm
100 ppm
Response time
Gas type
(T90)
Duration
Gases inflamables
20 s
5 years
Toxic substances
20 s
3 years.
Oxygen
10 s
2 years
Acoustic alarm
- 85 dB (A) at 1 m distance (intermittent tone)
- regular control tone
- prolonged tone in case of low battery.
Optical alarm
- very clear and flashing LED line
- Green LED with low flashing frequency as operational indicator (status: OK)
Pantalla
Two-line indicator with 24 letters or symbols respectively, high-contrast LCD with backlighting, displays up to 4 parameters at once, TWA alarm, peak value, low battery, real-time.
Data logger
Adjustable measurement rate, e.g. measurement time of 100 h with a measurement rate of 1 min until memory is full (maximum of 6000 values per parameter); place and user to be entered.
Interface for PC
yes, RS-232 (in connection with the optional data interface)
Software
Optional software compatible with Windows™ for easy device configuration (this configuration can also be done with the screen keys) as well as for transmitting data to the PC (data can be transmitted to other spreadsheet programs such as MS Excel)
Power supply
Rechargeable Ni Mh accumulator (minimum operating duration 12h), no memory effect / 1.2 Ah
Battery status indicator
yes, when the green LED emits a fast blink, it indicates that the battery charge is low.
Condiciones ambientales
- 20 ... + 50 °C / 0 ... 95 % H.r. without condensation
Housing class
IP 65
Dimensions
118 x 167 x 73 mm
Peso
900 g
Standards/Codes
Ex ias IIC T4 / Class I, Division I, Groups A, B, C,
D / EN50014, EN50020, SFA3009 / UL913 / CSA 22.2 / EN50081-2/ EN50082-1 / Sira 02 ATEX 2176X Ex ib d IIC T4
Calibration / Recalibration
The calibration of the device can be routinely carried out using the automatic calibration function or with the Windows-compatible PC software.
You can also send us the gas detector for recalibration and maintenance according to the instructions in your internal ISO manual (e.g., annually).
The device will be disassembled, cleaned, and recalibrated. We will inform you when a sensor cannot be recalibrated or has exceeded its lifespan. Of course, we have replacement sensors.
Examples of use for the Triple Plus gas meter
This Triple Plus gas detector with internal data memory complies with all European and international regulations, including the corresponding ATEX protection for measuring flammable gases such as CH.4.