AUTOCLAVE VERTICAL AES 110, 110 LITERS
Temperature adjustable from 105 °C to 139 °C. Presion maxima: 2,5 bar. SEGURIDAD • Independent device that prevents opening the autoclave lid while there is pressure in the sterilization chamber. • Safety thermostat for over-temperature. • Safety valve. Releases pressure in case it exceeds the maximum limit. Adjustable temperature from 105 °C to 139 °C. Maximum pressure: 2.5 bar. CARACTERISTICAS • Steam sterilization autoclave, with single chamber. • Automatic air purge, governed by the • Capacity for 10 sterilization programs. Microprocessor. • Funcionamiento automatico. • Manual drain valves for dewatering. • Exterior cabinet and countertop in AISI 304 stainless steel. Supplied with protective perforated rack • Tank, lid, and closure in AISI 316 stainless steel. of the heating element and without baskets. • Electric heating with shielded resistance in the chamber itself. • BSP1/2” threaded hole with cap, to allow the introduction of probes for the validation or calibration of the autoclave. (Accessible from the back). • Pt 100 class A temperature sensor • Temperature control with microprocessor with P.I.D. action • Silicone seal on the lid. MICROPROCESSOR FUNCTIONS The LCD screen continuously indicates the process parameters. It shows the program number, temperature, and time, and on the second line provides information about the phase of the sterilization cycle. Thus it is visualized with a cycle in progress: • PURGE-HEATING: Air purge and heating. • HEATING: Heating and pressure increase. • STERILIZING: sterilization period upon reaching the programmed temperature, and while the sterilization time lasts. • COOLING: Cooling phase (due to natural heat loss) that lasts from the end of the sterilization time until the END OF PROCESS. • END OF PROCESS: Notification of the end of the sterilization cycle which does not occur until the autoclave chamber reaches 95 ºC, at which point the lid can be opened. PROGRAMAS PROTEGIDOS The autoclave comes from the factory with four protected programs, which are the most commonly used in sterilization practice, and are as follows: Programs from P4 to P9 are left free for the user to program according to their needs. STERILIZATION WARRANTY The microprocessor checks throughout the sterilization cycle that all phases of the cycle are carried out correctly. Thus, during a cycle, some error messages can be displayed on the LCD screen, which are: • PROBE FAILURE: Broken or faulty temperature sensor. • HEATING FAILURE: The autoclave has problems in the heating phase to the programmed temperature. • TEMPERATURE FAILURE: The autoclave has temperature maintenance issues during the sterilization phase. • POWER FAILURE: While the sterilization cycle was being performed, the autoclave lost electrical power. (This is not actually a malfunction. In any case, the sterilization cycle is aborted). Models AES-110 and AES-150 are only supplied for three-phase current 220V or 380V + neutral. - Capacity: 110 liters. - Internal dimensions (Diameter x Height in mm): 400 x 850. - External dimensions (Height x Width x Depth in mm): 1,330 x 630 x 730. - Consumo: 4.500. - Weight: 114 kg. INCLUYE
CONTACTENOS: 24 hours for sales, maintenance, calibration, certification...
|









contact with the import area through 