Three-phase wattmeter and energy meter (real-time) with logging.
on SD card, interface
The PCE-PA 8000 wattmeter allows you to measure and record the power of a single-phase or three-phase circuit. With the wattmeter, you can perform prolonged measurements. The measurement values are stored on an SD card in xls format. This allows for convenient analysis of the measurement values on the computer. The measurement rate can be freely adjusted between 2 and 7200 seconds. The wattmeter can also perform energy measurements as well as determine the power factor and phase angle. The clamps of the PCE-PA 8000 wattmeter can be used for cables with a conductor diameter of up to 50 mm. Therefore, this meter is ideal for use in power supply networks. The 3.7" display allows reading all measurement values. This enables quick analysis of the current measurement values and provides an overview of current, voltage, and power.
- 3-phase/4-wire network analysis,
3 fases/3 conductores, 1 fase/2 conductores,
1 fase/3 conductores
- Measurement of the actual effective current value
and voltage
- Measurement of active, apparent power and
reactiva
- Determination of the phase angle and the
power factor
- Measurement of active, apparent energy and
reactiva
- Voltage measurement up to 600V
- Current measurement up to 1200 A
- Meets safety standards
IEC 1010 and CAT III 600V
- Integrates a calendar with real-time
- Recording of measurement values in
tarjeta SD
- Data is stored in format
Excel for your convenient later evaluation
- Possibility of measurement on the PC in real time
real through the data cable
- Large 3.7" display
Technical specifications
Voltage measurement (AC V)
Measurement range
Resolution
Accuracy
10 V ... 600 V (fase a neutro)
0,1 V
±(0,5 % + 0,5 V)
10 V ... 600 V (fase a fase)
Current measurement (AC A)
Measurement range
Resolution
Accuracy
20 A
0,001 A (<10 A)
0,01 A (≥10 A)
±(0,5 % + 0,1 V)
200 A
0,01 A (<100 A)
0,1 A (≥100 A)
±(0,5 % + 0,5 A)
1200 A
0,1 A (<1000 A)
1 A (≥1000 A)
±(0,5 A + 5 A)
Power activa
Measurement range
Resolution
Accuracy
0 KW ... 9,999 KW
0,001 KW
±(1 % + 0,008 KW)
10 KW ... 99,99 KW
0,01 KW
±(1 % + 0,008 KW)
100 KW ... 999,9 KW
0,1 KW
±(1 % + 0,8 KW)
1 MW ... 9,999 MW
0,001 MW
±(1 % + 0,008 MW)
Power aparente
Measurement range
Resolution
Accuracy
0 KVA ... 9,999 KVA
0,001 KVA
±(1 % + 0,008 KVA)
10 KVA ... 99,99 KVA
0,01 KVA
±(1 % + 0,08 KVA)
100 KVA ... 999,9 KVA
0,1 KVA
±(1 % + 0,8 KVA)
1 MVA ... 9,999 MVA
0,001 MVA
±(1 % + 0,008 MVA)
Power reactiva
Measurement range
Resolution
Accuracy
0 KVAR ... 9,999 KVAR
0,001 KVAR
±(1 %+0,008 KVAR)
10 KVAR ... 99,99 KVAR
0,01 KVAR
±(1%+0,08 KVAR)
100 KVAR ... 999,9 KVAR
0,1 KVAR
±(1%+0,8 KVAR)
1 MVAR ... 9,999 MVAR
0,001 MVAR
±(1%+0,008 MVAR)
Active power
Measurement range
Resolution
Accuracy
0 KWh ... 9,999 KWh
0,001 KWh
±(1 % + 0,008 KWh)
10 KWh ... 99,99 KWh
0,01 KWh
±(1 % + 0,08 KWh)
100 KWh ... 999,9 KWh
0,1 KWh
±(1 % + 0,8 KWh)
1 MWh... 9,999 MWh
0,001 MWh
±(1 % + 0,008 MWh)
Apparent power
Measurement range
Resolution
Accuracy
0 KVAh ... 9,999 KVAh
0,001 KVAh
±(2%+0,008 KVAh)
10 KVAh ... 99,99 KVAh
0,01 KVAh
±(2%+0,08 KVAh)
100 KVAh ... 999,9 KVAh
0,1 KVAh
±(2%+0,8 KVAh)
1 MVAh... 9,999 MVAh
0,001 MVAh
±(2 %+0,008 MVAh)
Reactive power
Measurement range
Resolution
Accuracy
0 KVARh ... 9,999 KVARh
0,001 KVARh
±(2 %+0,008KVARh)
10 KVARh ... 99,99 KVARh
0,01 KVARh
±(2 %+0,08 KVARh)
100 KVARh ... 999,9 KVARh
0,1 KVARh
±(2 %+0,8 KVARh)
1 MVARh... 9,999 MVARh
0,001 MVARh
±(2%+0,008 KVAh)
Power factor
Measurement range
Resolution
Accuracy
0 ... 1
0,01
±0,04
Phase angle
Measurement range
Resolution
Accuracy
-180º ... 180º
0,1º
±1º
Frecuencia
Measurement range
Resolution
Accuracy
45 Hz ... 65 Hz
0,1 Hz
0,1 Hz
Generic technical specifications
Pantalla
3.7" LCD (320 x 240 pixels)
with LED backlighting
Measurable electrical magnitudes
AC V, AC A, potencia activa, potencia
apparent, apparent power, factor of
power, phase angle, mains frequency
Voltage measurement ranges
10 V ... 600 V AC, automatic range selection
Safety standards
IEC1010CAT III 600V
AC input resistance V
10 MΩ
Operating frequency with current clamps
40 Hz ... 1 kHz
Working frequency checked with clamps
of current.
45 Hz ... 65 Hz
Overload protection
AC V
720 V rms
AC A
1300 A
with current clamps
Memoria
Tarjeta SD
Measurement share
1 segundo
Data logging function
Real-time logging on the SD card
Measurement share
2 segundos ... 7200 segundos
Data output
USB or RS-232, depending on connection cable
Temperatura operativa
0 ºC ... 50 ºC
Humedad ambiental
<80 % H.r.
Power supply
8 x 1.5 V AA batteries / network component
Input current
Medidor: 300 mA DC
Current clamp: 34 mA DC
Maximum duct diameter
50 mm
Peso
Weight: 948 g (batteries included)
Current clamp: 467 g (cable included)
Dimensions
Medidor: 225 x 125 x 64 mm
Current clamp: 210 x 64 x 33 mm
Mordaza: 86 mm (exterior)
Contents of the shipment
1 x Wattmeter PCE-PA 8000
3 x current clamps
4 x Test leads
4 x Alligator clips
1 x 2 GB SD memory card
1 x Network component 9 V DC
8 x Pilas 1,5 V AA
1 x Transport case
Information:
Recommendation:
Metrological calibration certificate of:
Technical service and maintenance of:
Wattmeter
wattmeter
International calibration certificate:
220 US$
Preventive maintenance and verification:
35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025
30 US$
Repair, corrective maintenance, adjustment, update, and validation:
60 US$
Includes:
** 2-year warranty.
** Discounts for the sale of two or more Thermometer.
** Metrological calibration certificate for Thermometer.
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a:Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.