You are here

VERTICAL AUTOCLAVE AE 50 DRY, 55 LITERS

$ 16,460.00
  AE-75-DRY
PRECIO : Dolares Americanos 
 

COMPRE: 3 PASOS

 

 

1.-Print your quote indicated at the top left.

2.- Make the deposit to the account number indicated in the quote.

3.- Send the voucher or proof of deposit with your billing information to:  [email protected]

We bring the equipment to your facilities and train you in the correct use of the equipment. We also provide you with the certificateor calibration and warranty.  

Esta tienda admite pagos mediante PayPal.

que rendimos al Dios de Jacob.

 

 

AUTOCLAVE   VERTICAL AE 50 DRY, 55 LITERS

Temperature adjustable from 105ºC to 139ºC.

Presion maxima: 2,5 bar.

SEGURIDAD

Independent device that prevents opening the autoclave lid while there is pressure in the sterilization chamber.

Over-temperature safety thermostat.

Safety pressure switch. Disconnects heating in case of excessive pressure.

Safety valve. Releases pressure in case it exceeds the maximum limit.

CARACTERISTICAS

Steam sterilization autoclave, with a single chamber.

Exterior cabinet and countertop in AISI-304 stainless steel.

Deposit closure lid, made of stainless steel AISI-316.

Water reservoir for feeding the autoclave, with maximum and minimum level detector.

Automatic water filling in the sterilization chamber.

Air purge and final drying with vacuum system.

1/2” threaded hole with cap for probe insertion for validation (accessible from the back).

RS-232 output to connect a printer or to a PC.

Silicone gasket on the cover.

PT100 temperature sensor - class A

Temperature control with microprocessor with P.I.D. action.

Electric heating with armored resistance in the chamber itself.

Supplied with a protective perforated rack for the heating element and without baskets.

MICROPROCESSOR FEATURES AND FUNCTIONS

The STERILMATIC-C autoclaves are equipped with a microprocessor, the result of research and long experience as autoclave manufacturers, to meet the needs and demands of sterilization users. The microprocessor with a liquid crystal alphanumeric display indicates which phase of the process is being performed or what anomaly has occurred, prints sterilization data, as well as the date and time to validate the sterilized product. It accepts a second temperature probe to detect the actual temperature in the 'core' of liquids or in waste bags, thus sterilizing them effectively and correctly. In short, it has been designed to maximize the ease of sterilization.

Parametros programables:

Sterilization temperature.

Sterilization time.

Drying or not drying.

Drying time.

Sterilization mode: SOLIDS / LIQUIDS.

Printing of parameters.

 

Programming variables:

Number of programs: 10

Sterilization temperature: from 105 to 139 ºC.

Sterilization time: from 3 to 120 minutes.

Solids / Liquids. Drying / Non-drying.

Drying time: from 1 to 60 minutes.

When we run a program, the microprocessor screen, besides displaying the temperature and sterilization and drying time, indicates the phase of the sterilization cycle.

A complete sterilization cycle consists of the following phases:

VACUUM: Initial vacuum (air expulsion from the chamber).

FILLING: Automatic filling of distilled water in the sterilization chamber.

HEATING: Heating and pressure increase.

ESTERILIZANDO: Esterilizacion.

DISCHARGING: Automatic discharge of water and steam from the sterilization chamber to the distilled water tank.

DRYING: Vacuum drying and barometric leveling.

END OF PROCESS: Notice of the end of the sterilization cycle.

The microprocessor display will give us warning messages when, for example, the condensate tank does not have enough water, when the bacteriological filter needs to be changed, or when it is printing results. Likewise, if there is any anomaly during the execution of a program, apart from the program being aborted, it will give us a fault message, for example, due to a broken temperature sensor, if there is a fault during the filling period of the autoclave chamber, if there is a fault during the heating period, if the sterilization temperature differs by 2 degrees, either more or less, from the selected temperature, if there has been a power cut, etc. All these messages on the screen greatly assist the user in interpreting a possible anomaly. In liquid programs, the “draining” phase does not execute, and instead, there is the “cooling” phase (cooling by natural heat loss until the end process temperature). Likewise, in liquid programs, the “drying” phase does not exist as it is not possible to program a final drying.

 

DESCRIPCION TECNICA

End of process

Secando

Descargando

Esterilizando

Vacio

Calentando

- Capacity: 28 liters.

- Internal dimensions (Diameter x Height in cm): 30 x 70 cm

- External dimensions (Height x Width x Depth in cm): 125 x 51 x 56

- Consumo: 2500 W.

- Weight: 60 K.  
See technical sheet
 

INCLUYE

  • 2-year warranty.   
  • Preventive and corrective maintenance (repair) of autoclaves and spare parts during the warranty.
  • Metrological Calibration Certificate for Autoclaves.
  • Great discounts on the price for the sale of 2 or more autoclaves.
  • Shipping to all of Peru and Latin America.

CONTACTENOS: 24 hours for sales, maintenance, calibration, certification...

  •  Correo   :  [email protected]
  •  Telefonos  Lima - PERU    
  •  Moviles : Claro 940788823  Movistar 945139699 Entel 998383788
  •   Radio   :  Entel 51*838*3788                                    

Regresar a lista Regresar a lista  de                                                       Return to Catalog of autoclaves                                                          All autoclaves

 

Price: $ 16,460.00