AUTOCLAVE VERTICAL AES 75, 75 LITERS
Temperature adjustable from 105 °C to 139 °C. Presion maxima: 2,5 bar. SEGURIDAD Independent device that prevents opening the autoclave lid while there is pressure in the sterilization chamber. Over-temperature safety thermostat. Safety valve. Releases pressure if it exceeds the maximum limit. Adjustable temperature from 105 °C to 139 °C. Maximum pressure: 2.5 bar. CARACTERISTICAS Steam sterilization autoclave, with a single chamber. Automatic air purge, governed by the Capacity for 10 sterilization programs. Microprocessor. Funcionamiento automatico. Manual drainage valves for desorption. Exterior cabinet and countertop in stainless steel AISI 304. Supplied with protective perforated rack Tank, lid, and closure in stainless steel AISI 316. of the heating element and without baskets. Electric heating with armored resistance in the chamber itself. BSP1/2” threaded hole with cap, to allow the introduction of probes for validation or calibration of the autoclave. (Accessible from the back). Temperature sensor Pt 100 class A Temperature control with microprocessor with P.I.D. action. Silicone gasket on the cover. MICROPROCESSOR FUNCTIONS The LCD screen continuously indicates the process parameters. It shows the program number, temperature, and time, and on the second line provides information about the phase of the sterilization cycle. Thus it is visualized with a cycle in progress: PURGE-HEATING: Air purge and heating. HEATING: Heating and pressure increase. STERILIZING: sterilization period upon reaching the programmed temperature, and while the sterilization time lasts. COOLING: Cooling phase (by natural heat loss) that lasts from the end of the sterilization time until the END OF PROCESS. END OF PROCESS: Notice of the end of the sterilization cycle which is not performed until the autoclave chamber is at 95 ºC, at which point the lid can be opened. PROGRAMAS PROTEGIDOS The autoclave comes from the factory with four protected programs, which are the most commonly used in sterilization practice, and are as follows: Programs from P4 to P9 are left free for the user to program according to their needs. STERILIZATION WARRANTY The microprocessor checks throughout the sterilization cycle that all phases of the cycle are carried out correctly. Thus, during a cycle, some error messages can be displayed on the LCD screen, which are: PROBE FAILURE: Broken or faulty temperature sensor. HEATING FAILURE: The autoclave has problems in the heating phase up to the programmed temperature. TEMPERATURE FAILURE: The autoclave has issues maintaining temperature during the sterilization phase. ELECTRIC CUT: While the sterilization cycle was being carried out, the autoclave lost electrical power. (This is not a malfunction. In any case, the sterilization cycle is aborted). Models AES-110 and AES-150 are only supplied for three-phase current 220V or 380V + neutral. Capacity: 75 liters. Internal dimensions (Diameter x Height in mm): 400 x 600. External dimensions (Height x Width x Depth in mm): 1,090 x 620 x 730. Consumo: 3000 W. Weight: 85 kg. INCLUYE
CONTACTENOS: 24 hours for sales, maintenance, calibration, certification...
|









contact with the import area through 