Robust, easy-to-use wattmeter with multimeter, oscilloscope, and data logger function
The FLUKE 125/S wattmeter is a robust device for fault location in industrial environments. This wattmeter integrates an oscilloscope, a multimeter, and a paperless 'recorder' into a single, affordable, and easy-to-use device. The wattmeter is the right equipment to troubleshoot machines, instrumentation, and electrical control and supply systems. In today's complex systems, a numerical measurement does not provide enough information to determine the cause of a failure. Anomalies in signals, voltage drops, and unexpected failures that can cause a machine to stop are better visualized with an oscilloscope. The FLUKE 125/S meets the current needs to measure and simultaneously check waveforms. The unique Connect-and-View™ trigger mode automatically displays stable waveforms for virtually any imaginable signal. It provides stable, reliable, and repeatable visualization of almost any signal, including control signals and variable speed drives, without the need to press a button.
- Oscilloscope bandwidth 40MHz
- TRMS digital multimeter with two channels and 5,000 digits
- Automatic measurements
- Two channels with TrendPlot™
- Automatic Connect-and-View™ trigger types for easy measurement
- Shielded test cables for oscilloscope modes, resistance measurements, and continuity
- 10:1 - voltage probe for high frequency measurements
- Battery life up to 7 hours
- Seguridad EN61010-1 CAT III 600 V
- Optically isolated interface for PC connection
- Compact and robust equipment
- Measurement of VDC, VAC, VAC+VDC, Ohms, Continuity, Diode check, Current, °C, °F, Capacitance, dBV, dBM, Crest factor, Touch Hold and Zero adjustment
- Includes bus status test function and power measurement
- FlukeView Software for post-analysis of measured values
Technical specifications
Model
ScopeMeter FLUKE 125/S
Bandwidth of the oscilloscope
40 MHz
True RMS multimeter with two channels
VDC, VAC, VAC+VDC, Ohms, Continuity, Diode check, Current, °C, °F, Capacitance, dBV, dBM, Crest factor, Touch Hold, and zero adjustment.
Registro TrendPlot
Automatic vertical scale and temporary compression.
Presentation of actual readings of minimums, maximums, and average.
Cursores
∆T, 1/∆T, V, ∆V, rise and fall time
Max. real-time sampling rate
25 MS/s
Equivalent sampling speed
up to 2.5 GS/s (125, 124) or 1.25 GS/s (123)
Channels and digitizers
2
Time base range
20 ns -1 min/div
Input sensitivity
5 mV -500 V/div
Types of trigger
Connect-and-View™, Free, Single shot, Edge, Video, External
Peak capture
40 ns
Oscilloscope measurements
26 automatic measurements, W, VA, VAR, and PF for balanced single-phase and three-phase electrical systems (in triangle)
Harmonic frequency range.
CC up to the 33rd harmonic (fundamental up to 60 Hz);
CC up to the 24th harmonic (fundamental up to 400 Hz).
Maximum recording length
512 min./max. input points
Memoria
20 displays and settings
Working temperature
0 ... 50 ºC
Storage temperature
-20 ... +60 ºC
Altitud
3.000 m
Seguridad
Seguridad EN61010-1 CAT III 600 V
Dimensions
232 x 115 x 50 mm
Peso
1,2 kg
Warranty
3 years on parts and labor (one year on accessories).