Powerful FLUKE 43B oscilloscope for network and power supply analysis

The FLUKE 43B oscilloscope is an instrument that combines the functions of an electrical power quality analyzer, an oscilloscope, a multimeter, and a data logger in one device. This oscilloscope has everything needed to identify problems with tripping circuit breakers, overheating transformers, burnt motors, machines that do not operate correctly, whatever the issue. With the electrical power quality analyzer function, it is optimized for industrial measurements at the fundamental frequency of 50 Hz. Since its fundamental frequency range extends from 10 to 400 Hz, it is also ideal for aerospace, naval, and railway applications. The measurement results can be viewed and analyzed on the large graphical display of the oscilloscope.

- Energy measurement (W, VA, VAR) and power factor (PF, DPF) 

- Power and power factor in balanced three-phase loads

- Harmonics of voltage, current, and power up to the 51st order

- Measurement of cycle-to-cycle fluctuations for up to 24 hours

- Automatically captures up to 40 transients in just 40 ns

- Measures motor starting current. Measurement with sliders

- Covers a wide frequency range (10 to 400 Hz) 

- 2-channel oscilloscope

- Bandwidth of up to 20 MHz with VPS40 voltage waveform

- Automatic "Connect-and-View" trigger for waveform visualization

  instantaneous and stable

- On-screen cursors for signal analysis

- Measures resistance, continuity, capacitance, and checks diodes.

- Measures temperature with optional temperature probes (Fluke 61 infrared thermometer)

  included only with Fluke 43B) 

- Records up to 2 parameters over a period of up to 16 days

- All measured parameters can be recorded, including V/A/Hz, all aspects of

  energy and harmonics and all oscilloscope measurements

- Stores up to 4000 tension events with the VR101S (Fluke 43B Kit)

- 20 measurement memories to save and retrieve screens and data with cursor readings

- Calculates three-phase power in balanced loads from a single-phase measurement

- Measures power harmonics and captures voltage fluctuations, transients, and currents of

  entrada

- Monitoring functions help track intermittent problems and the

  electrical system performance

- Menus use common electrical terminology

- Can switch between the most commonly used feed quality modes with just a press 

  one key

- Records two selectable parameters over a period of up to 16 days

- FlukeView software can log harmonics and other readings over time

- FlukeView software provides a complete profile of harmonics up to the 51st

- Measures resistance, diode voltage drop, continuity, and capacitance

- NIMH battery that increases operating time to 6.5 hours

- Complete package with voltage probes and 400 A clamp meter, FlukeView software

  and optically isolated communication cable

Technical specifications

V/A/Hz

Useful bandwidth: 10 Hz ... 3.5 kHz

Harmonics at fundamental frequency of 400 Hz: 9.

Normal accuracy for fundamental frequency of 40: 5 %

Power, battery life

Useful bandwidth: 20 Hz ... 2 kHz

Harmonics in fundamental frequency of 400 Hz: 5.

Normal accuracy for fundamental frequency of 40: 10%

Harmonics

Useful bandwidth: 10 Hz ... 3.5 kHz

Harmonics at fundamental frequency of 400 Hz: 9.

Normal accuracy for fundamental frequency of 40:

10% Canal 1, 50% Canal 2

Input features

Input impedance: 1 MΩ, 20 pF

Voltage indication: 600 V eff, CAT III

Voltage/Current/Frequency

True RMS voltage (AC/DC)

Range: 5 V, 50 V, 500 V, 1250 V

Accuracy: ± (1% + 10 Digits)

Corriente RMS real (AC/DC)

Range: 50 A, 500 A, 5 kA, 50 kA

Accuracy: ± (1% + 10 Digits)

Frecuencia

Range: 40 to 15.9 kHz

Accuracy: ± (0.5 % + 2 Digits)

CF crest factor

Range: 1,0 - 10,0

Accuracy: ± (0.5 % + 1 Digit)



Power

 

Power efectiva (W),

Power aparente (VA),

Power reactiva

Single-phase, three-phase, balanced loads of 3 conductors

Range: 250 W to 1.56 GW

Accuracy: ± (4 % + 4 Digits) Power fundamental component

Accuracy: ± (2 % + 6 Digits) Total power

Power factor

Range: 0 - 1,0

Accuracy: ± 0,04

Displacement power factor, cos j

Range: 0,25 - 0,9

Accuracy: ± 0,04

Range: 0,9 - 1,0

Accuracy: ± 0,03

Frecuencia fundamental

Range: 40 to 70 Hz

Accuracy: ± (0.5 % + 2 Digits)



Harmonic indication

 

Voltage, current, frequency

Fundamental up to the 51st harmonic

Fundamental accuracy:

Apparent power ± (3 % + 2 Digits)

Active power: ± (5 % + 2 digits)

Accuracy of the 2nd to 31st harmonic:

Apparent power: ± (5 % + 3 digits)

Active power: ± (10 % + 10 Digits)

Precision of the 32nd to 51st harmonic:

Apparent power ± (15 % + 5 Digits)

Active power ± (30% + 5 digits)

Frecuencia fundamental

Range: 40 Hz to 70 Hz

Accuracy: ± 0,25 Hz

Fase

Range: Voltage, Current (fundamental frequency and harmonics)

Accuracy: ± 3° up to ± 15°

Range: Active power (between fundamental voltage and current harmonics)

Accuracy: ± 5° up to ± 15°

K-Factor (Current and active power)

Range: 1 to 30

Accuracy: ± 10 %

(THD)

Range: 0 to 99.99

Accuracy: ± (3 % + 8 Digits)



Fluctuaciones

 

Recording time

From 4 minutes to 16 days (selectable)

Real Vrms, max. Vrms, min (AC + DC)

Range: 5 V, 50 V, 500 V, 1250 V

Accuracy: Readings ±(2% +10 Digits); 

Cursor readings ±(2% + 12 Digits)

Real Vrms, max. Vrms, min.

Range: 50 A, 500 A, 5 kA, 50 kA

Accuracy: ± (2 % + 10 Digits)



Transient capture

 

Minimum pulse width

40 ns

Useful bandwidth, input 1

DC a 1 MHz

Number of transients

40

Threshold voltage adjustments

20%, 50%, 100%, 200% above or below the reference signal



Resistencia, Capacidad, Diodo, Continuidad

 

Resistance range

500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ37;

Resistance accuracy

± (0.6 % + 5 Digits)

Capacity range

50 nF, 500 nF, 5 µF, 50 µF, 500 µF

Capacity accuracy

± (2 % + 10 Digits)

Diode voltage

Accuracy ± (2 % + 5 Digits)

Continuidad

The buzzer activates at < 30 Ω ± 5 Ω

Max current.

0,5 mA



Input current

 

Input current time

1 s, 5 s , 10 s, 50 s, 100 s, 5 min

Current range

1 A, 5A, 10 A, 50 A, 100 A, 500 A, 1000 A

Accuracy

± 5 % of full scale



Temperatura (con accesosrios)

 

Rango

-100 °C to +400 °C

Accuracy

± (0.5 % + 5 Digits)



Oscilloscope display

 

Mediciones

dc, ac, ac+dc, peak, peak to peak, frequency, duty cycle, phase, pulse width, crest factor

Time range

20 ns/div a 60 s/div

Max. sampling rate.

25 MS/s

Bandwidth

Voltage channel [1]

20 MHz on the inputs, 20 MHz with the VPS40 probe (included with the Fluke 43B), 1 MHz with the TL24 cables

Current channel [2]

15 kHz at the inputs, 10 kHz with the included current probes

Acoplamiento

AC, DC (10 Hz - 3 dB)

Sensibilidad vertical

5 mV/div to 500 V/div

Vertical resolution

8 bit (256 niveles)

Recording length

512 measurements per channel

Time base modes

Normal, Roll, Single

Base time range

60 s/div a 20 ns/div

Time base accuracy

± (0.4% + 1 pixel)

Sampling rate

25 MS/s

Log length

(min. / max. samples)

512 per channel

Trigger

Input 1 or 2 or automatic selection

Modo Trigger

Automatic with Connect-and-View, free operation, and single shot

Connect-and-View

Advanced automatic activation that recognizes signal patterns and automatically adjusts activation, time base, and amplitude.

Automatically displays stable images of complex and dynamic signals, such as motor drive and control signals.



Memoria



20 (pantallas, ajustes, datos)



Recording

 

Recording time

From 4 minutes to 16 days (selectable)

Parameters

Select one or two parameters from one of the following groups:

Voltios/Amperios/Hz

Active power (W), apparent power (VA), reactive power (VAR), power factor, displacement power factor, frequency, harmonics, THD, voltage (fundamental frequency and harmonics), current (fundamental frequency and harmonics), active power (fundamental frequency)

Frequency (Harmonics), % (Harmonics) of the total value, Phase (Harmonics), Kf

Temperatura

Resistencia, Diodo, Continuidad, Capacidad

Oscilloscope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty Cycle + or -, Max Peak, Min Peak, Min-Max Peak, Crest Factor



Environmental specifications

 

Working temperature

0 °C to +50 °C



Safety certification

 

Electrical safety

EN 61010-1 CAT III, 600 V. CSA certified



Mechanical and general specifications

 

Dimensions

232 x 115 x 50 mm

Peso

1,1 kg

Warranty

3 years.

Battery life

Rechargeable Ni-MH battery (charger included), typical 6 hours of duration (continuous operation)

Duration: 6.5 hours

Charging time: 7 hours

Shocks and vibrations

Mil 28800E, Type 3, Category III, Class B

Briefcase

IP51 (dust, splashes, water tightness)

Contents of the shipment:

1 x Osciloscopio FLUKE 43B

1 x Test cable TL224, 

1 x Set of AC220 crocodile clips, 

1 x Set of extra-fine TP4 test tips, 

1 x BP120MH Battery, 

1 x Conector tipo banana a BNC BB120, 

1 x PM 8907 power supply/battery charger, 

1 x i400s ammeter probe, 

1 x Large jaw crocodile clips AB200, 

1 x TP1-1 test probe set, 

1 x C120 transport case, 

1 x OC4USB interface cable,

1 x Software FlukeView SW43W, 

1 x Voltage probe VPS 40,

1 x Fluke61 infrared thermometer,

1 x User Manual and application guide

Information:             

Metrological calibration certificate of:

Technical service and maintenance of:
Osciloscopio  Osciloscopio
Certificado de calibración CAL-LCR
International calibration certificate:    220 US$ Preventive maintenance and verification:   35 US$
Calibration certificate from EQUINLAB SAC calibration laboratory - Standard 17025 30 US$ Repair, corrective maintenance, adjustment, update, and validation:                       60 US$

Includes:
** 2-year warranty.
** Discounts for the sale of two or more Osciloscopio.
** Metrological calibration certificate for Osciloscopio.
** Preventive maintenance, corrective (repair), technical service, and spare parts.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a: Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.
Quick contact:     Ventas@equinlabsac.live mail     info@equinlabsac.live mail

 

Price: $ 6,600.00