You are here

Anesthesia Machine BT-2000J5

$ 0.00
          Origin: China                                                  Pedido N° ref.: BT-2000J5
 Shipping: to all of Latin America Delivery time: Inquire 

ANESTHESIA MACHINE

Anesthesia machine, 10.4 inches

BT-2000J5

TECHNICAL SPECIFICATIONS

Physical specifications

Display: 10.4'' LCD screen Modo suitable for adults and children

: pneumatic and electrically controlled system

Working mode: closed; Semicerrado; Semiabierto

Circuit standards integrated breathing circuit

Flow Meters: 5 Tubes Consumption Indicators: O2: 0.1 ~ 10L/Min, N2O: 0.1 ~ 10L/min; Air: 0.1 ~ 10L/Min

Trolley: Equipped with 4 anti-static rubber wheels; two of which are lockable for braking and easy maneuverability with foot-operated brake provisions

Drawer unit with 2 fully removable drawers

Technical specifications:

Gas requirement: medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32 ~ 0.6MPa; NO2: 0,32 MPa a 0,6 MPa.

safety valve <12.5 kPa

Frecuencia respiratoria 1 ~ 99bpm

oxygen concentration in the mixed gas N2O / O2 > 21%

Oxygen discharge: 25 ~ 75 L/min

ventilation modes A / C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL, SIGH

PEEP: 0 ~ 2.0 kPa

Inspiratory activation pressure -1.0 kPa ~ 2.0 kPa

Frecuencia IMV: ..

I / E ratio: 8: 1 ~ 1:10, has the inverse ventilation ratio

Volumen corriente 0 ~ 1500 ML

Inspiratorio Meseta: 0 ~ 1s

O2 concentration: 21% ~ 100%

Sigh: a deep breath for 70 ~ 120 controlled breaths, the inspiration time is 1.5 times the set point

Maximum safety pressure: ≤ 12.5 kPa

Pressure limit range: 0 ~ 6.0 kPa

Airway pressure alarm: Audible and visual with yellow and red indicating Lower: 0.2kPa ~ 5.0kPa; Superior: 0.3 ~ 6.0 kPa ± 0.2 kPa

Current volume alarm: audible and visual with yellow and red color indicating the upper alarm: 50 to 2000 ml, lower alarm: 0 ~ 1800ml

Oxygen concentration alarm: audible and visual with yellow and red color indicating upper alarm: 21% ~ 100%; alarma inferior: 10% ~ 80%

Power supply alarm "The AC/DC power supply is produced after not sending the alarm immediately

Alarm time: keep > 120 s"

The airway pressure remains above 15 hPa \ pm 1 hPa for 15 s ± 1 s, then the machine will emit an audible alarm, the pressure will be displayed in red and the continuous red alarm phrase for high pressure will be shown on the screen of the anesthetic respirator.

Operating conditions

Temperatura ambiente: 10 ~ 40oC

Relative humidity: not exceeding 80%

Atmospheric pressure: 860 hPa ~ 1060 hPa

Power requirement: 100-120 Vac, 50/60 Hz;

Attention: the AC power supply used for the anesthesia machine must be properly grounded.

Attention: the used anesthesia machine must be equipped with a carbon dioxide monitor that complies with ISO 9918: 1993, an oxygen monitor that complies with ISO 7767: 1997, and a gas volume monitor that complies with 51.101.4.2 of the medical electrical equipment Part II: Special requirements for the safety and basic performance of anesthesia systems.

Almacenamiento

Temperatura ambiente: -15 °C ~ + 50°C

Relative humidity: no more than 95%

Atmospheric pressure: 86 kPa ~ 106 kPa.

Must be stored in a room without corrosive gas and well-ventilated. packaging box of the paquete meets the requirements of GB / T 15464

Between the packaging box and the product, soft material of appropriate thickness is provided to prevent loosening and friction during transport.

.

Alarm for oxygen from safety and alarm Alarm when the oxygen supply from the pipe or cylinders is below 0.2MPa

Lower ventilation volume alarm: 0 ~ 12L / Min; Arriba:

Power alarm of 18L / min . Alarms while AC and DC power fails; Maintain elongation time: > 120s

Lower air duct pressure alarm: 0.2 kPa ~ 5.0 kPa; Arriba: 0.3kPa ~ 6.0kPa

Certification

RU DAN01

Registration certificate for the Multiparameter Monitor

Certificado de Cumplimiento DAN01

Certificate of Compliance 

Declaración de conformidad DAN01

Declaration of conformity 

More information:               

 

Includes:
** 2-year warranty.
** Discounts for the sale of two or more Anesthesia machines.
** Metrological calibration certificate for Anesthesia machines.
** Preventive, corrective maintenance (repair)  Anesthesia machines.
** Sales, maintenance, calibration, certification, and technical service 24 hours.
Envios a: Argentina, Bolivia, Brasil, Chile, Colombia, Costa, Rica, Cuba, Ecuador, El Salvador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Paraguay, Peru, Puerto Rico, Dominican Republic, Uruguay, Venezuela.
Quick contact:     [email protected] mail     [email protected] mail

 